Cathodic Protection Monitoring Equipment      

DR-2™ Dual Reference Cell

Polatrak® Cathodic Protection Monitoring
in conjunction with Deepwater Corrosion Inc.

A rugged dual element reference electrode to provide CP status for 20 years.

 

Product Overview

The Deepwater Polatrak DR-2 is a rugged dual-element reference electrode designed to provide CP status for 20 years. Hundreds of these electrodes are in reliable service all over the world.

The current DR-2 has an improved machined black Delrin body, which enhances the impact resistance of the assembled instrument.

A sintered Ag/AgCl reference electrode provides very accurate potential data to monitor polarization of the structure. A heavy-duty zinc electrode element serves as a long-term, ultra-reliable, low-resolution electrode.

The dual-element (Ag/AgCl sw / Zinc) reference electrode is designed for weld-on, bolt-on or clamp-on attachment to an offshore structure.

Designed for permanent monitoring of cathodic protection systems, the electrode has a 20-year design life. Added to the back of the instrument is a 10 square foot current density monitoring array, such that polarization data may be logged directly from the instrument.

Available remote control monitoring systems are standard on new structures. Polatrak systems give you the option to tie into communication lines, providing remote cathodic protection monitoring over existing infrastructure.

Applications

  • Offshore platform jackets & drill rigs.
  • Seawater ballast tanks on SPAR, TLP, and FSU / FPSO structures.
  • SPAR center well area.
  • Inshore structures, piers, jetties, wharves.
  • Subsea equipment wired to SunStation™ permanent readout.
  • As impressed current CP controller.
  DR-2 dual reference cell

The DR-2 dual reference cell is equipped with one Ag/AgCl and one Zn reference electrode for unparalleled accuracy.

DR-2 Dual Reference Cell in fabrication.

DR-2 Mark 1 in situ. The casing has been replaced by black Delrin on the current version, Mark 2.


Main Benefits

  • Structures with permanent CP monitoring systems can be inspected subsea much less frequently.
  • The rugged design allows the system to be preinstalled or retrofitted.
  • The double steel wire armored cable can be free routed on offshore structures thus saving cost of conduit or duct systems.
  • The dual elements combine high accuracy ±0.005V with proven longevity.
  • Available with integrated current density monitor (product ID: DR-2–CD).

Specifications

Zinc Electrode Material
Dimensions
Weight
Anti-passivation
Accuracy
Zinc (high purity 99.95%)
6 x 5 x 11.5"
12 lbs (5.45 kg)
Embedded carbon steel rods
±0.02 V
Ag/AgCl  Electrode Material
Dimensions
Weight
Accuracy
Sintered Ag/AgCl w/ silver wire core
0.47" dia. x 0.20" (12 mm dia. x 5 mm)
0.09 oz (2.5 g)
±0.005 V
Electrode Housing Material
Dimensions
Black Delrin
18" x 5" x 4" (45.7 x 12.7 x 10.2 cm)
Cable Encapsulation Type Cold-mold soft polyurethane made inside embedded PVC condulet within electrode housing.
Electrode Frame Material
Coating
Conduduit interface
ASTM A36 carbon steel
Marine epoxy
2" pipe coupling or 2" 150# blind flange
Cable Type
 
OD
Bend radius
Weight/foot in air
2 x #12 AWG PVC insulated, PU bedded, DGSWA, HMWPE sheathed
0.560" (1.4 cm)
9" (23 cm)
0.366 lb (0.167 kg)
0.260 lb (0.120 kg)


For further information on this product: www.stoprust.com

Alduco are the sole Distributor of Deepwater products in the Gulf of Guinea.

Deepwater Logo